... least diameter at the point of a pile shall be six inches . The least diameter of the butt of a pile shall be twelve inches , except that where a pile is less than twenty - five feet in length , such butt diameter may be ten , or more ...
... least diameter at the point of a pile shall be six inches . The least diameter of the butt of a pile shall be twelve inches , except that where a pile is less than twenty - five feet in length , such butt diameter may be ten , or more ...
Страница 733
... least one inch away from any woodwork , and if less than two inches away , the woodwork shall be protected by sheet ... least three hours and whose ceiling has a fire resistive rating of at least one hour . b . Solid or gas fuel in grate ...
... least one inch away from any woodwork , and if less than two inches away , the woodwork shall be protected by sheet ... least three hours and whose ceiling has a fire resistive rating of at least one hour . b . Solid or gas fuel in grate ...
Страница 770
... least six feet deep shall be left behind the last row of seats on the main floor . The total space in lobbies , foyers and promenades shall be at least one and one - half square feet per person . § C26-757.0 Exits from motion picture ...
... least six feet deep shall be left behind the last row of seats on the main floor . The total space in lobbies , foyers and promenades shall be at least one and one - half square feet per person . § C26-757.0 Exits from motion picture ...
Садржај
Table of Sections With Page References | xxii |
Chapter 928 | xxxvii |
Chapter 929 | 1 |
други делови (64) нису приказани
Друга издања - Прикажи све
Чести термини и фразе
amount application approved assessment avenue beams board of estimate borough president building car safety certificate charter city collector column combustible commissioner comply comptroller concrete construction corporation counsel counterweight court designed device distance dollars dumbwaiter duty East One hundred East river elevator enclosure exit factor of safety Fahrenheit fee title fifty filed fire resistive rating fireproof floor fund gypsum height hoistway doors inches incombustible issued landing least license live load load located masonry material maximum means of egress ment metal notice one-half operation owner paid partitions payment pension permit person pounds per square premises proceeding real property reinforcement retirement roof safety sidewalk square inch stairways steel storage street structure SUB-ARTICLE subdivision superintendent tax lien taxicab thence therein thereof thereto tion transfer of tax unlawful vomitories walls width